Affected Component: EQUIPMENT:APPLIANCE:AIR CONDITIONER

Date Published
NOV 01, 2013
NHTSA TSB #
10150184
TSB Document
Summary
A/C Cooling: Intermittent Reduction of Air Flow. The customer may complain of reduced air flow when the air conditioning system is operated for an extended time, usually longer than one hour. The complaint can vary due to one or more of the following variables: * High outside ambient temperature * Too much humidity * A/C temperature and fan settings set too low for too long Note: It is very difficult to duplicate this issue due the required outdoor weather conditions and length of driving time needed. CAUSE Evaporator starts to freeze up due to the position of the evaporator temperature sensor