Affected Component: ELECTRICAL SYSTEM

Date Published
JAN 01, 2015
NHTSA TSB #
10147595
TSB Document
Summary
SUBJECT DME Internal and Valvetronic Faults Set at Cold Ambient Temperatures. The Service Engine Soon light (MIL) can be illuminated with the erroneous internal and Valvetronic faults stored in the DME. The MIL will only come on if the fault has been detected on two (or more) consecutive drive cycles. The following fault codes may be stored in the DME: E Seriesz 36AE - DME, internal fault, Valvetronic: Current implausible One or more of the following secondary faults may also be stored: z 2DE2 - Valvetronic, actuation, voltage phase: Line disconnection z 2DE3 - Valvetronic, actuation, volt phase: Line disconnection z 2DE4 - Valvetronic, actuation, volt phase: Line disconnection F Seriesz 1F0905 - DME, internal fault, Valvetronic: Current implausible One or more of the following secondary faults may also be stored: z 135B10 - Valvetronic, actuation, voltage phase: Line disconnection z 135B11 - Valvetronic, actuation, volt phase: Line disconnection z 135B12 - Valvetronic, actuation, volt phase: Line disconnection Engine performance and driving characteristics are not affected. DME software diagnostic sensitivity.