Engine Stall Immediately Following Fuel Tank Fill-Up (X60 Warranty Extension)
This bulletin involves replacing the fuel tank and vapor canister.
Some customers may experience an engine stumble or stall condition which occurs
immediately after filling the fuel tank. The integral multi-functional control valve may stick
allowing liquid fuel to enter the evaporative emissions system causing a rich fuel condition
when the purge system is initiated.