"Service bulletin - The telematics system is reporting deterioration of the fuel cell stack. This deterioration can reduce fuel cell output. Water improperly discharged inside the fuel cell stack mixes with hydrogen and oxygen, generating hydrogen peroxide. The hydrogen peroxide/water combination concentrates in one area, accelerating the deterioration of the electrolyte membrane in the fuel cell."