10.0
really awful- Crashes / Fires:
- 0 / 4
- Injuries / Deaths:
- 0 / 0
- Average Mileage:
- 68,497 miles
About These NHTSA Complaints:
The NHTSA is the US gov't agency tasked with vehicle safety. Complaints can be spread across multiple & redundant categories, & are not organized by problem. See the Back button — blue bar at the very top of the page — to explore more.
« Read the previous 20 complaints
HVAC fan motor stopped running at approximately 72,000 miles on 2008 Honda Ridgeline rtl; no fire, smoke or smell. Took to dealer to troubleshoot, and advised wiring harness connector had melted (asked for part back, and observed large grey connector was melted/burned at the largest blue-on-white wire). Repair cost $190.26, but am concerned that HVAC fan, and possibly other HVAC compents, may also be damaged and may need to be replaced--working fine now. Have searched online and found that this is fairly common issue with Ridgeline's, was subject to safety recall for 2006 thru 2007 models of specific manufacture dates, but seems to still continue to occur though the 2008 models as well--appears to be factory defect, and feel american Honda should reimburse all with this issue. Defintely could be serious fire and safety hazard.
- Sour Lake, TX, USA
2008 Honda Ridgeline blower fan stopped working due to failure of wiring harness with melted connector. The 2008 model year is not covered by recall for same problem for previous Honda Ridgelines (2005-07).
- Calgary, 00, USA
The contact owned a 2008 Honda Ridgeline. The vehicle was parked and shut off for a few minutes when the contact noticed a fire started on the instrument panel near the passenger side. The fire department responded to extinguish the fire and a police report was filed. No injuries were reported but the vehicle was destroyed due to fire damage. The vehicle was towed to an insurance lot where they were in the process of diagnosing the failure. The failure and current mileages were 50,500. The VIN was unavailable.
- Elk Grove Village, IL, USA
The blower fan on my 2008 Honda Ridgeline recently quit working. The dealership found that the wiring harness had melted causing the fan to stop working. The wiring harness was replaced. I did not receive the old harness.
- Lees Summit, MO, USA
2008 Honda Ridgeline fan blower motor failed causing wiring harness and resistor to fail. Wiring harness melted but fuse did not blow. This is a definite fire and smoke hazard. There are many other instances of this same exact problem in 2006 - 2008 my vehicles.
- St. Joseph, MI, USA
Possible fire hazard: A/C stopped working on 22nd of August. Dealer ship said that the wiring harness melted and blower fan seized. The fuse did not blow. They said they are also going to replace the transistor on the circuit. The car is a 2008 Honda Ridgeline rtx with 15000 miles on it. The high temperature was 86 F.
- Francestown, NH, USA
The air conditioner on my new 2008 Honda Ridgeline stopped working. Truck had 4,000 miles at the time. I brought it to the dealership and was told that a wire inside the dash board had melted and that a wire harness needed to be replaced. Repairs were made under warranty and problem is resolved but I was lucky not to have a fire.
- Missouri City, TX, USA
- Raymond, NH, USA