Certain 2022-2023MY IONIQ 5 (NE1) and 2023MY IONIQ 6 (CE1) vehicles may exhibit a condition where low 12V auxiliary battery charging occurs due to an ICCU (Intelligent Charging Control Unit) fault which may set the following DTC P1A9096 â âDC/DC Converter Input Voltage Sensor Faultâ. When a fault occurs, the vehicle may enter a reduced power mode while various warning lights, an audible chime will sound, and large messaging in the vehicleâs instrument cluster will appear, instructing the driver to stop the vehicle. The vehicle will be inspected for a DTC P1A9096 and may require either an ICCU software update or ICCU replacement and potential fuse replacement (if fuse is blown when inspected).