Flash: Dosing Control Unit (DCU) Updates
This bulletin involves reprogramming the Dosing Control Unit (DCU) with the latest available software.
Customers may experience a Malfunction Indicator Lamp (MIL) illumination. Upon further investigation, the technician may find one or more of the following Diagnostic Trouble Codes (DTCs) have been set: P0563-00 - System Voltage High(2020 M6 Vehicles only). P21CC-00 - Reductant Control Module Supply Voltage High(2020 M6 Vehicles only). P24B2-00 - Particulate Matter Sensor Circuit Intermittent. P20F6-00 - Reductant Injection Valve Stuck Open Bank 1 Unit 1. P208E-00 - Reductant Injector Stuck Closed - Bank 1 Unit 1. Incompatible software between the DCU, Powertrain Control Module (PCM) and BCM causing a false illumination of the Malfunction Indicator Lamp (MIL). Additional customer concerns:Engine Stop/Start (ESS) not functioning properly. Four wheel drive not functioning.