Flash: 6.7L Diagnostic And System Improvements
This bulletin involves reprogramming the Powertrain Control Module (PCM) with new software.
Several software improvements are available for vehicles equipped with a Cummins 6.7L turbo diesel. They are as follows:Prevent Or Reduce Malfunction Indicator Lamp (MIL) Illumination When No Defect is Present For The Following Diagnostic Trouble Codes (DTCs). These Faults Have Been Changed From
A One Trip Fault To A Two Trip Fault:
P0201 - P0206 - Fuel Injector X Circuit Open Fault Codes.
U110E - Lost Ambient Temperature Message.
P049D - EGR Control Position Exceeding Learning Limit.
P226C - Turgocharger Boost Control ?A? Slow Response.The Following DTC Has Been Changed From A Two Trip Fault To One Trip Fault:
U1A24 - Lost Communication With Ammonia Sensor.Improvements To Prevent Or Reduce Malfunction Indicator Lamp (MIL) Illumination When No Defect Is Present