alright well you see the code for the 3-4 solenoid.the solenoid is not the problem. if u look at the power distribution center you will see the trans control relay and that relay is good.terminal 86 is giving power but 85 in turn is not grounding at the pcm i know this because the pwer coming from terminal 30 is not making it to terminal 87 wich means that the tran is not receiving the trans control relay output. witch is a red wire. all the wires check out but im not sure why the pink wire # 85 will ground letting the relay switch over so the power will make it to the trans.WHAT THE HELL DO I DO. plus the guy already put a new pcm in it. it worked good for about 30 min then bam 3-4 solenoid right back
alright well you see the code for the 3-4 solenoid.the solenoid is not the problem. if u look at the power distribution center you will see the trans control relay and that relay is good.terminal 86 is giving power but 85 in turn is not grounding at the pcm i know this because the pwer coming from terminal 30 is not making it to terminal 87 wich means that the tran is not receiving the trans control relay output. witch is a red wire. all the wires check out but im not sure why the pink wire # 85 will ground letting the relay switch over so the power will make it to the trans.WHAT THE HELL DO I DO. plus the guy already put a new pcm in it. it worked good for about 30 min then bam 3-4 solenoid right back
- beganma, Dennis, MA, US