5.3
fairly significant- Crashes / Fires:
- 0 / 0
- Injuries / Deaths:
- 0 / 0
- Average Mileage:
- 17,454 miles
About These NHTSA Complaints:
The NHTSA is the US gov't agency tasked with vehicle safety. Complaints can be spread across multiple & redundant categories, & are not organized by problem. See the Back button — blue bar at the very top of the page — to explore more.
Surging, lack of power, stalling, no start condition
- Fremont, CA, USA
I have a 1998 Ford Windstar, and its fuel tank was leaking into the passenger compartment. When brought to the dealer it was said that the fuel tank collapsed at the fuel pump, which caused the leaking.
- Newark, OH, USA
There are wires going through fuel tank that have no cover, and it could cause a fire. Dealer notified. The vehicle had stalled several times due to wires shorting out in the fuel pump. The fuel pump was replaced.
- Lenexa, KS, USA
Fuel pump has stopped working due to insulation on wires wore off, which in some cases could result in a fire. Contacted dealer.
- Park Valley, UT, USA
Fuel pump inside fuel tank is not working properly. There is a wire inside fuel tank connected to fuel pump, and within 50000 miles wire started to rub together with potential of there being a fire in fuel tank. Contacted dealer, and the dealer was not willing to do anything.
- Monticello, AK, USA
I had a fuse blow on my fuel pump.this pump is in the tank and the tank was full.when the mechanic removed the tank he found two wires with thethe coatings burnt off.a pieceof one wire was welded to one of the tubes.this could have caused a fire or if the tank wasnot full more likely an explosion.it is fused with 25amp.I believe this to be avery dangerous condition.ihave the pump also pictures of same.please keep me advised of your findings.if you need more info just call or E-mail.
- Gilman, VT, USA
Fuel pump fuse blew which could have caused a fire.
- Bath, NY, USA
1st to 2nd bang when shifting on slow acceleration (repeats often), fuel pump continually cuts out when parked on slight downhill, still 6+ gallons left. Only since replacement of fueltank and gas pump due to electrical short
- Nutley, NJ, USA
IE99059, the defective steering bushings does not support the system which causes the vehicle steering system to malfuction. Also, braking system malfunctioned, causing extended stopping distance which may result in a crash. The fuel pump went out unexpectedly, cause vehicle to stall. Finally, liftgate indicator light came on, but the liftgate remained closed. Brakes been replace once, and bushings 3 times. Please provide further information and VIN#.
- High Park, MA, USA
For no apparent reason the vehicle just cuts off while driving. The first time a computer adjustment was made, the second time(July 23rd) the electric fuel pump was replaced. The vehicle is being service for the third time(Aug 5th) for the same problem. Each time the vehicle had to be towed to the dealership.
- Burnsville, MN, USA
Fuel pump failed.
- Palacios, TX, USA
While driving 30 mph down hill the fuel pump will shutdown, which was caused by a short in the sensor of the fuel tank. Dealer replaced the fuel pump and the tank. Consumer states that the tank was a 25 gallon tank, however the sensor was causing the low fuel light to come on when only 16-17 gallons had been consumed.
- Wareham, MA, USA
- Negaunee, MI, USA